Every comfortzone electric underfloor heating thermostat should be set up with a floor temperature sensor probe to monitor the temperature of your floor.
Floor temperature sensor resistance.
Sensor wire should be between 7 000 ohms to 14 000 ohms.
Always ensure resistance matches the information on the product tag.
The thin casing allows for retrofit installation between tile spaces if necessary.
Set the multimeter for resistance at 10k ω 2 at room temperature and take a reading between the sensor leads.
Test 4 temperature sensor.
The floor temperature sensor does not seem to be working properly.
Please check the resistance values of your current sensor against the table cable has high rigidity allowing it to be easily passed through existing flexible conduit.
The 3m remote sensor probe can be used with all of our thermostats that accept a remote sensor.
Suitable for use in wet areas ip68.
Warmup heating cables are constant wattage cables that should be tested on a 200 ohm scale.
It can be used to measure air or floor temperature and is specifically designed to be used as a floor sensor.
With the digital multimeter scale set at 20k ohms the ohms reading of the.
Test the floor temperature sensors using a multimeter to verify accuracy of the sensors.
The resistance will vary according to the temperature i e the colder the sensor the higher the resistance.
The floor sensor may be damaged or may not be in the proper location with the sensor tip placed halfway between heating wires.
3 meter floor temperature sensor probe for underfloor heating thermostat features works with a wide range of different thermostats.
Pull the latch for the hood and open it making sure it is secure before letting go.
The slab sensor 079 is commonly used for floor temperature sensing in floor heating applications.
This sensor is designed to provide a thermostat with the ability to maintain a minimum slab temperature or help to limit the maximum slab temperature.
Replacement floor temperature sensor suitable for a wide range of underfloor heating thermostats.
Check the thermostat floor temperature sensor cable by disconnecting the floor sensor cable from the thermostat measure the sensor cable resistance in ohms using a digital multimeter.
Works with a wide range of different thermostatsplease check the resistance values of your current sensor against the table below for compatibility 3 metre long cable cable has high rigidity allowing it to be easily passed through existing flexible conduit suitable for use in wet areas.
Installing a new sensor is typically easier than moving or repairing the existing sensor.
Try temporarily hooking up a new sensor to the control.