Fire sprinkler system to be electronically monitored by u l.
Fire sprinkler system riser diagram.
8 fire department connection.
Automatic sprinkler system risers fire pumps and controllers shall be provided with ready access.
Riser key notes 1 5 0 ductile iron stub out feed 2 thrust block.
System description the dry pipe sprinkler system is a fire protection system that utilizes water as an extinguishing agent while the system piping from the dry pipe valve to the automatic fusible sprinklers is filled with pressurized air or nitrogen.
St d5020 3 motor control center anchorage under structural above st g4010 01.
Dry pipe sprinkler system february 12 2010 page i.
However one of the benefits of the alarm valve is that it allows the waterflow switch to be installed or replaced without draining the sprinkler system.
Fire sprinkler risers are in a sense where the plumbing outside a building ends and a fire sprinkler system begins.
Of 7 0 a f f.
This system is a modification to the one detailed in nfpa 14 figure a 7 1 b.
Otherwise known as an fdc or siamese connection since there are two inlets on the connection this connection is located on the exterior of the building.
Therefore the sprinkler system can remain in service while the flow switch is being replaced.
To account for the required residual pressure at the 24th floor while maintaining a pressure below 175 psi on the lower floors a two zone low pressure and high pressure system utilizing a single fire pump was designed for the building.
All valves shall be a max.
Where located in a fire pump room or automatic sprinkler system riser room the door shall be permitted to be locked provided the key is available at all times.
Provide pipe hangers and sway bracing on all fire sprinkler system piping and equipment per nfpa 13 as.
Listed central station for flow tamper and trouble.
Fire alarm riser diagram.
On any sprinkler system that does not meet exceptions for being inaccessible large capacity deluge systems or single story buildings not over 2 000 sqft 185 sq m.
Connection used by the fire department to pump water into the fire sprinkler or standpipe system to supplement the building s water supply.
Telephone data equipment closets and riser diagram.
Hydraulically calculate the wet pipe sprinkler systems per nfpa 13 and ufc 3 600 01 density and spacing listed in the sprinkler design criteria table below.
Nfpa 13 2002 8 16 2 2 2007 16 8 17 2 2 2019 16.
A vane type flow switch can be used just like on a straight pipe riser system.
Then it conveys that water to the network of pipes running to fire sprinkler heads.
Allows the fire department to supply supplementary pressure and flow to the system during a fire event.
Small building telecommunications room plan and telecommunications riser diagram.