Striping signs or other markings when approved by the fire code official shall be provided for fire apparatus access roads to identify such roads or prohibit the obstruction thereof.
Fire riser room signage requirements.
6 6 4 identification of valves.
The following are example suggestions to some but not necessarily all of our signage requirements.
Rooms containing controls for air conditioning systems sprinkler risers and valves or other fire detection suppression or control elements shall be identified for the use of the fire department.
The national fire protection association nfpa 13 standard for the installation of sprinkler systems specifies many different requirements for the types of signage that sprinkler systems must include.
Clear signage will help firefighters act quickly to assist building occupants.
You are required to have a tactile sign next to each door inside a stairwell.
During a fire every minute counts.
Approved signs required to identify fire protection equipment and equipment location shall be constructed of durable materials permanently.
Because of this make sure the fire sprinkler riser room sign is easy to see.
Signage is required on the access doors to fire pump and riser.
What is clear is that they are required for your system to be in compliance with the.
The fire sprinkler riser assembly the fire alarm control panel fire alarm manual pull station spare sprinkler heads storage box and the document box for as built drawings shall be located within the room.
If the room has a lock then the key needs to be always available to those who need to access the room.
Do i need ada compliant signs in the stairwells of my building.
7 inches high by 10 inches width with 0 5 inch letter stroke white reflective letters on a red background and shall be permanently attached at normal eye level to the door leading to the fire sprinkler control equipment.
Fire sprinkler riser room sign purpose and materials.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
What s new is fire pumps controllers and risers shall be readily accessible within the room and to those who access the room.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Section 6 6 4 of nfpa 13 stipulates sign requirements for all control drain venting and test connection valves while section 8 16 1 1 expands on the guidance for control valves.
You should check with your local code authority.
For instance the town of brighton n y stipulates the following for fire sprinkler riser room signage.
These signs should identify the foor level stair level and exit level.
Minimum requirements fire riser room the fire equipment room shall be located within the building footprint.
The requirements in the code vary from sign to sign and their purpose isn t always immediately clear.
Check local building codes to learn about fire sprinkler fire pump and fire alarm control.
Most fire sprinkler system valves must be identified with metal or rigid plastic signs.
From the 2016 edition of nfpa 13.