Tomatic sprinkler system riser rooms and fire pump rooms.
Fire pump room door size.
Nfpa 20 provides for protection of the fire pump equipment as well as for personnel that need to access the fire pump equipment during a fire situation.
If a fire pump room is not directly accessible from the outside it shall be accessible through a fire resistant rated corridor from an enclosed stairway or exterior exit.
This room shall have an external door shall be installed inside the building with a door providing access into the fire equipment.
An important part of the standard is that location and access to the fire pump room shall be pre planned with the fire department.
Automatic sprinkler system risers fire pumps and controllers shall be provided with ready access.
The door must be labeled as the riser room.
The fire rating can be reduced to a one hour rating when the fire pump enclosure is located in a fully sprinkled non high rise building.
Where lo cated in a fire pump room or automatic sprinkler system riser room the door shall be permitted to be locked provided the key is available at all.
Chapter 4 in nfpa 20 standard for the installation of stationary pumps for fire protection also has separation requirements for the fire pump room basically for high rise it s 2 hr for non high rise it s 1 hr.
Nfpa 20 requires the fire pump room to have a minim um two h ou r fire rating when located in a high rise building.
2018 code 901 4 6 4 901 4 6 1 access.
While nfpa 20 requires that access to the fire pump room be pre planned with the fire department it now requires that the location of the fire pump room also be pre planned.
Buildings with single tenants may access the riser location from the interior of the building.
The pump room or pump house must a floor drain that will discharge to a frost free location.
The pump room must be provided with a door and unobstructed passageway large enough to allow removal of the largest piece of equipment.
All fire sprinkler riser rooms shall be a minimum of 36 sq.