These doors must stay closed in the event of a fire.
Fire door threshold detail.
Floor levels versus threshold levels.
Doors up to 4 0 wide and 8 0 tall can use standard weight 134 thickness ball bearing hinges.
All fire rated doors must include an automatic latching mechanism.
Door clearances at the door edge of the door frame wood door on the pull side of the door do not exceed clearances listed in 4 8 4 the clearance under the bottom of the door shall be a maximum of 3 4 and 6 3 1 top edges 1 8 metal door top edges up to 3 16.
Thresholds are rarely mandated by the codes and standards for fire doors or smoke doors but when they are used in these applications thresholds must be listed to ul 10c or nfpa 252.
Bs9999 2008 recommends for fire doors with cold smoke control that the threshold gap should be either less than 3mm in height or should be fitted with a threshold seal.
180 thickness latches locks.
Backbend return face stop soffit rabbet throat.
Doors over 4 0 wide and 8 0 tall must use heavyweight hinges.
These all show sills positioned at floor level ie not rebated.
Protection association for fire doors and fire windows nfpa 80 and the door components installation instructions.
E2 as1 includes general door sill details figures 17c and 17d and specific door sill details for masonry veneer figure 73d.